13, in 4 sections

Lights and siren

  1. Emergency warning lights operationalPass or fail · photo every timeSwitch on every warning light. Photograph them running. Every lamp flashes, none cracked or missing.
  2. Siren operational, every tonePass or failWail, yelp and horn. Clearly heard outside the vehicle.

Breathing apparatus

  1. Breathing apparatus functional test passedPass or fail · out of service if it fails
  2. Face seal and valves intactPass or fail
  3. Cylinder pressureReading against your limit
  4. Cylinder hydrostatic testExpiry dateEnter the date on the tag or label. Warns 30 days before.
  5. Spare cylindersCount against your par level

Self-rescuers

  1. Self-rescuersCount against your par level
  2. Self-rescuer seals intactPass or fail
  3. Self-rescuer serviceExpiry dateEnter the date on the tag or label. Warns 30 days before.

Gas detection

  1. Gas detectors bump testedPass or fail
  2. Gas detector calibrationExpiry dateEnter the date on the tag or label. Warns 30 days before.
  3. Gas detector batteries chargedPass or fail

Checked by ______________________   Date and time ______________   Unit ______________

No limit is shown here on purpose: set each from the maker’s manual or your own procedure. A starting point: change the items to match your procedure before you rely on them.

What this checklist asks for

Takes the unit out of service

As the starter is set, a fail on any of these takes the unit out of service until the defect is cleared. You can change what any item does.

  • Breathing apparatus functional test passed

Takes a number against your limit

The limit is yours to set; until you do, the number is kept with no pass or fail.

  • Cylinder pressure
  • Spare cylinders
  • Self-rescuers

Needs a photo every time

Taken live on the phone and kept with the answer.

  • Emergency warning lights operational

Questions about this checklist

What does the breathing apparatus and gas detection weekly checklist cover?

13 items in 4 sections: lights and siren, breathing apparatus, self-rescuers and gas detection.

What happens when an item fails in Escudo Mining?

As the starter is set: 1 item takes the unit out of service and 12 items restrict it when they fail; the rest are recorded. You can change what any item does. A failure asks for a photo on 6 items, and the defect goes to the people who fix it.

Does the breathing apparatus and gas detection weekly come with limits?

No. 3 items take a number against a limit (cylinder pressure, spare cylinders and self-rescuers), and each limit is yours to set from the maker’s manual or your own procedure. Until you set one, the number is still recorded.

Run it on the phone instead of paper

Open it from the unit’s tag, with or without signal. A failed item becomes a defect with a photo and sets the status as your template says.

Send us your own version of this check

We will build it into Escudo Mining with your items and your rule pack, and show it running on a phone underground with no signal.