Set

  1. Set ID or serialNoteType the number on the label or tag. Stands in for a scan.
  2. Cooling or ice fittedPass or failWhere the set uses cooling. Remove this item where it does not apply.
  3. Electronic monitor displayPhotoPhotograph the display after the check. Remove this item for a set without an electronic monitor.

Oxygen

  1. Oxygen cylinder pressureReading against your limit · out of service if it fails · photo every timeRead the set’s gauge and photograph it. Set your minimum from the maker’s manual and your procedure.

Absorber

  1. CO2 absorber fittedPass or fail · out of service if it fails
  2. Absorber use-by or fill dateExpiry dateThe date on the canister or the fill label. Warns 30 days before.
  3. Tests or wears since the absorber was filledReading against your limitSet your maximum from the maker’s limit.

Tests

  1. High pressure leak test passedPass or fail · out of service if it fails
  2. Low pressure leak test passedPass or fail · out of service if it fails
  3. Bypass and lung demand valve workPass or fail · out of service if it fails
  4. Warning signal sounds at the set pressurePass or fail · out of service if it failsThe pressure the maker sets for the warning.

Mask

  1. Mask, straps and seals in good conditionPass or fail

Result

  1. Set resultChoose one · out of service if it fails

Checked by ______________________   Date and time ______________   Unit ______________

No limit is shown here on purpose: set each from the maker’s manual or your own procedure. A starting point: change the items to match your procedure before you rely on them.

What this checklist asks for

Takes the unit out of service

As the starter is set, a fail on any of these takes the unit out of service until the defect is cleared. You can change what any item does.

  • Oxygen cylinder pressure
  • CO2 absorber fitted
  • High pressure leak test passed
  • Low pressure leak test passed
  • Bypass and lung demand valve work
  • Warning signal sounds at the set pressure
  • Set result

Takes a number against your limit

The limit is yours to set; until you do, the number is kept with no pass or fail.

  • Oxygen cylinder pressure
  • Tests or wears since the absorber was filled

Needs a photo every time

Taken live on the phone and kept with the answer.

  • Electronic monitor display
  • Oxygen cylinder pressure

Questions about this checklist

What does the closed-circuit breathing apparatus pre-use check cover?

13 items in 6 sections: set, oxygen, absorber, tests, mask and result.

What happens when an item fails in Escudo Mining?

As the starter is set: 7 items take the unit out of service and 4 items restrict it when they fail; the rest are recorded. You can change what any item does. A failure asks for a photo on 7 items, and the defect goes to the people who fix it.

Does the closed-circuit breathing apparatus pre-use check come with limits?

No. 2 items take a number against a limit (oxygen cylinder pressure and tests or wears since the absorber was filled), and each limit is yours to set from the maker’s manual or your own procedure. Until you set one, the number is still recorded.

Run it on the phone instead of paper

Open it from the unit’s tag, with or without signal. A failed item becomes a defect with a photo and sets the status as your template says.

Send us your own version of this check

We will build it into Escudo Mining with your items and your rule pack, and show it running on a phone underground with no signal.

Or email us: info@escudoready.com