All checklistsChecklist
Refuge chamber routine inspection
The routine inspection of a refuge chamber on the site’s schedule, for example weekly: access, air, door seals, battery, systems, inventory and the emergency plan. A fail on air, oxygen, scrubbing or communications marks it not ready.
- Items
- 23, in 7 sections
Chamber
- Chamber IDNoteType the number on the label or tag. Stands in for a scan.
- Next maker service dueExpiry dateFrom the service label on the chamber. Warns 30 days before.
Access
- Access clearPass or fail
- Signage visible and green strobe workingPass or fail
Air and door
- Mine air connected through the filtersPass or fail · out of service if it fails
- Mine air supply pressureReading against your limit
- Door seals intact, door closedPass or fail · out of service if it fails
Power
- Battery able to give the rated hoursPass or fail · out of service if it failsFrom the battery monitor or tester.
- Battery conductance readingReading against your limitFrom the battery tester. Set your minimum from the maker.
Systems
- Lights workPass or fail · out of service if it fails
- Air conditioning worksPass or fail · out of service if it fails
- Call test to surface by radio or phonePass or fail · out of service if it fails
Inventory
- First aid kit sealedPass or fail
- Oxygen therapy supply readyPass or fail · out of service if it fails
- Stretcher aboardPass or fail
- Gas monitor, or pump and tubes, readyPass or fail · out of service if it fails
- Scrubbing chemicals sealedPass or fail · out of service if it fails
- Oxygen candles aboardPass or fail · out of service if it failsFor a chamber that uses candles. Remove this item where it does not apply.
- Drinking waterCount against your par level
- Toilet and sanitation suppliesPass or fail
- Gas monitor calibrationExpiry dateEnter the date on the tag or label. Warns 30 days before.
- Earliest consumable expiryExpiry dateThe earliest date across the scrubbing chemicals, candles, food, water and first aid. Warns 30 days before.
Records
- Current emergency plan on boardPass or fail
Checked by ______________________ Date and time ______________ Unit ______________
No limit is shown here on purpose: set each from the maker’s manual or your own procedure. A starting point: change the items to match your procedure before you rely on them.