Skip to content
Book a demo
Items
23, in 7 sections

Chamber

  1. Chamber IDNoteType the number on the label or tag. Stands in for a scan.
  2. Next maker service dueExpiry dateFrom the service label on the chamber. Warns 30 days before.

Access

  1. Access clearPass or fail
  2. Signage visible and green strobe workingPass or fail

Air and door

  1. Mine air connected through the filtersPass or fail · out of service if it fails
  2. Mine air supply pressureReading against your limit
  3. Door seals intact, door closedPass or fail · out of service if it fails

Power

  1. Battery able to give the rated hoursPass or fail · out of service if it failsFrom the battery monitor or tester.
  2. Battery conductance readingReading against your limitFrom the battery tester. Set your minimum from the maker.

Systems

  1. Lights workPass or fail · out of service if it fails
  2. Air conditioning worksPass or fail · out of service if it fails
  3. Call test to surface by radio or phonePass or fail · out of service if it fails

Inventory

  1. First aid kit sealedPass or fail
  2. Oxygen therapy supply readyPass or fail · out of service if it fails
  3. Stretcher aboardPass or fail
  4. Gas monitor, or pump and tubes, readyPass or fail · out of service if it fails
  5. Scrubbing chemicals sealedPass or fail · out of service if it fails
  6. Oxygen candles aboardPass or fail · out of service if it failsFor a chamber that uses candles. Remove this item where it does not apply.
  7. Drinking waterCount against your par level
  8. Toilet and sanitation suppliesPass or fail
  9. Gas monitor calibrationExpiry dateEnter the date on the tag or label. Warns 30 days before.
  10. Earliest consumable expiryExpiry dateThe earliest date across the scrubbing chemicals, candles, food, water and first aid. Warns 30 days before.

Records

  1. Current emergency plan on boardPass or fail

Checked by ______________________   Date and time ______________   Unit ______________

No limit is shown here on purpose: set each from the maker’s manual or your own procedure. A starting point: change the items to match your procedure before you rely on them.

What this checklist asks for

Takes the unit out of service

As the starter is set, a fail on any of these takes the unit out of service until the defect is cleared. You can change what any item does.

  • Mine air connected through the filters
  • Door seals intact, door closed
  • Battery able to give the rated hours
  • Lights work
  • Air conditioning works
  • Call test to surface by radio or phone
  • Oxygen therapy supply ready
  • Gas monitor, or pump and tubes, ready
  • Scrubbing chemicals sealed
  • Oxygen candles aboard

Takes a number against your limit

The limit is yours to set; until you do, the number is kept with no pass or fail.

  • Mine air supply pressure
  • Battery conductance reading
  • Drinking water

Questions about this checklist

What does the refuge chamber routine inspection cover?

23 items in 7 sections: chamber, access, air and door, power, systems, inventory and 1 more.

What happens when an item fails in Escudo Mining?

As the starter is set: 10 items take the unit out of service and 12 items restrict it when they fail; the rest are recorded. You can change what any item does. A failure asks for a photo on 16 items, and the defect goes to the people who fix it.

Does the refuge chamber routine inspection come with limits?

No. 3 items take a number against a limit (mine air supply pressure, battery conductance reading and drinking water), and each limit is yours to set from the maker’s manual or your own procedure. Until you set one, the number is still recorded.