All checklistsARFF Ready · Checklist
Breathing apparatus set daily check
Each shift, for each breathing apparatus set: cylinder pressure, high pressure leak test, warning whistle, mask, demand valve, harness and distress signal unit.
- Items
- 9, in 4 sections
Cylinder
- Set cylinder pressureReading against your limit · out of service if it failsRead the set’s gauge. Set your minimum from the rated fill pressure.
- Pressure drop over 60 secondsReading against your limit · out of service if it failsOpen the cylinder, close it, then watch the gauge for 60 seconds.
- Cylinder hydrostatic testExpiry date · out of service if it failsEnter the date on the tag or label. Warns 30 days before.
Warning devices
- Low pressure warning whistle soundsPass or fail · out of service if it failsVent slowly. It sounds at the manufacturer’s set point.
- Distress signal unit operatesPass or fail · out of service if it fails
- Telemetry or tally, if fittedPass or fail
Mask and demand valve
- Face mask visor, straps, exhale valve and sealPass or fail · out of service if it fails
- Demand valve gives positive pressure, bypass worksPass or fail · out of service if it fails
Harness
- Harness, straps and backplatePass or fail
Checked by ______________________ Date and time ______________ Unit ______________
No limit is shown here on purpose: set each from the maker’s manual or your own procedure. A starting point: change the items to match your procedure before you rely on them.
Send us your own version of this check
We load your vehicles, zones and the templates you choose, you validate them in your own words, and your crews start checking. Tell us about your airport.